Specification:
Application General Chemical Fume Section Hood
Design Basis Comply to ASHRAE-110 Standards for face velocity
CE, ISO 13485:2016, ISO 9001:2015, ISO
14001:2015, ISO 45001:2018, IEC 61010-1, IEC
60601-1, BS EN 12469:2000, U.S. FDA, RoHS &
WHO-GMP CERTIFIED
Certifications
Fume Hood Structure Aerodynamic Floor Mounted.
Air Flow Type Low Constant Volume Exhaust Type
<60db sound levels (Blower to be mounted on a
remote mounting kit)
Noise Level (At Main Body)
Construction Double Skinned
Structure Outer Skin (MOC) Super Structure constructed out of CRC Powder Coated.
Work Top Traditionally our work tops are made of thick DISHED
CORED Granite, thicker at MARINE EDGES, thus
preventing spillages and accidental damages. These
chemical resistance splash & spilledge proof Granite
work top are having skirting from all the side, to prevent
chemical spillage outside the work area.
Cup Sink Made of PP/Porcelain Sink, to collect chemical waste
on Work top.
Inner Chamber Vertical Liner Chemical & Heat Resistance, Fire retardent, smooth
finish, easily cleanable, panel made out of PRL integral
work (6mm thick).
Epoxy Powder Coating Powder coated with highly chemical resistant epoxy
colors.
Baffle Unique designed removeable back baffle captures and
removes or slides fumes instantly at much faster
speed.
Utility Valves (Option) Our Valves have fine control over utilities as per international standards and withstands 200 PSI
pressure & brass fitting for gas connections.
1 No. for Water, 1 No. for Nitrogen, 1 No. Compressed Air, 1 No. for Vacuum.
Suction 3-point suction system (for light, normal and heavy fumes) with baffle and finned horizontal slots
aids in distributing the flow of air.
Airfoil Aerodynamic Design, Horizontal fixed airfoil mounted on work top, made up of SS-304, provides
spill retention and safe ventilation of fumes generated with ergonomic design.
TECHNICAL SPECIFICATIONS
Exhaust Collar Craftly tapered and flanged exhaust collar reduces airflow turbulances induces high static
pressures reduces noise levels to minimal and also increases face velocity exhaust.
Exhaust Port A Unique design pattern of Exhaust Port ensures that the fumes will get exhausted smoothly
without any turbulance at exhaust port, even it takes care of low noise as well.
Electric Utility 2 Nos. 15 Amp. Sockets & Switches.
1 No. MCB Switch for the Blower.
Lighting Fluroscent light (40 Watt x 2 Nos.) with vapour- Proof for proper illumination. Intensity approx
400lux on work top.
Front Top Panel Easly openable panel, to access Damper & to light fixture, for maintenance purpose.
Motor Heavy duty motor, 3 Phase TEFC, IP55, class F continuous rated.
Maximum Air Exhaust Air Volume Minimum face velocity of 0.5m/s or 100 fpm at defined sash position
Centrifugal Blower SISW type, Chemical & heat resistance heavy duty epoxy coated blower with aerodynamically
balanced Impeller, with Drain plug. Consisting of continuous rating motor and chemical resistant.
Blower will give face velocity of 80 to 100 Feet/minute (FPM) and a high static pressure at defined
sash position. It satisfies all national and international safety velocity norms.
Base Cabinet Heavy Duty
PP/FRP Blower
Apparatus Holding Grid
(Scaffolding)
(Chemical Resistant)
Polypropylene
Sink With Tap
DIN
Remote Valves Utility Connections Degree Nozzle